Product Description:
Digital ® NUCLEAR NUKE RADIATION METER READER
Nuclear Radiation Detector NR3000B
Main Technical Properties:
1. Low-energy response can be enhanced after energy compensation of G-M counting tube.
2. This instrument has a high sensibility and so will have response to environment background.
3. Applicable radiation occasions: χ Ray and γ Ray.
4. Measuring range: dosage rate of 0.01usv/h - 5msv/h; accumulated dosage (5 digit liquid crystal display) of 000.01usv - 999.99msv. 5. Energy response: <±30%?50KeV1.3MeV?.
6. Relative basic error: <±10%?137Cs source: 622KeV; γ radiation:1 msv/h?.
7. Response Time of Warning: ≤3s
8. Warning function: warning of dosage rate threshold value --- 0.5, 1.0, 2.5, 10, 30, 50 usv/h.
9. This instrument has memory function of accumulated dosage, which can still permanently save the data in memory after power outage and perform 1,000,000 times of memory and erasion.
10. Indication of Cell undervoltage: cell voltage icon is displayed in the top right corner of LCD.
If electric quantity identifying is full of three grids, cell electric quantity is about 2.8 - 3.2V.
If electric quantity identifying accounts for two grids, cell electric quantity is about 2.5 - 2.8V.
If electric quantity identifying accounts for one grid, cell electric quantity is about 2.1 - 2.5V.
If electric quantity identifying doesn’t account for grid, cell electric quantity is about 2.1V below, which means the cell is under voltage.
11. Working environment requirement: temperature of -10~+50°C; moisture of 90% (without condensation).
clips, 9V battery and
Domestic sales and dealership and Export/Import inquiries are welcome, please contact the following:
Nuclear Radiation Detector NR3000B
Main Technical Properties:
1. Low-energy response can be enhanced after energy compensation of G-M counting tube.
2. This instrument has a high sensibility and so will have response to environment background.
3. Applicable radiation occasions: χ Ray and γ Ray.
4. Measuring range: dosage rate of 0.01usv/h - 5msv/h; accumulated dosage (5 digit liquid crystal display) of 000.01usv - 999.99msv. 5. Energy response: <±30%?50KeV1.3MeV?.
6. Relative basic error: <±10%?137Cs source: 622KeV; γ radiation:1 msv/h?.
7. Response Time of Warning: ≤3s
8. Warning function: warning of dosage rate threshold value --- 0.5, 1.0, 2.5, 10, 30, 50 usv/h.
9. This instrument has memory function of accumulated dosage, which can still permanently save the data in memory after power outage and perform 1,000,000 times of memory and erasion.
10. Indication of Cell undervoltage: cell voltage icon is displayed in the top right corner of LCD.
If electric quantity identifying is full of three grids, cell electric quantity is about 2.8 - 3.2V.
If electric quantity identifying accounts for two grids, cell electric quantity is about 2.5 - 2.8V.
If electric quantity identifying accounts for one grid, cell electric quantity is about 2.1 - 2.5V.
If electric quantity identifying doesn’t account for grid, cell electric quantity is about 2.1V below, which means the cell is under voltage.
11. Working environment requirement: temperature of -10~+50°C; moisture of 90% (without condensation).
clips, 9V battery and
Domestic sales and dealership and Export/Import inquiries are welcome, please contact the following:
Unit 79, Grace Park Commercial Complex
4th Ave. West bet. J. Teodoro & A. Del Mundo Streets
Grace Park, Kalookan City 01406
Metro-Manila, NCR, Philippines
Tel. Nos.: 63 2 324 1091, 63 2 364 7586, 63 2 367 1712, 63 2 385 3493, 63 2 986 2283
Facsimile: 63 2 365 4686
Mobile No./SMS: 63 920 969 2672
E-mail Address: gadgetsandgears@yahoo.com
Yahoo IM: BrandPhilippines
Skype: BrandPhil1
URL: GADGETSANDGEARS.com
Like us on facebook at http://www.facebook.com/GadgetsandGearsdotcom
Compared Ad

Title