Bante 820 Portable Dissolved Oxygen Meter

Ad Information
Ad Description
?
Bante 8 series portable meters uses polarographic electrode to
measures dissolved oxygen in water, it can shows the oxygen
level as % saturation from 0 to 200% or concentration from 0 to
20mg/L.
Automatic Calibration
The meters can be calibrated at one or two points - in air(100%)
and / or with a zero oxygen solution, easy and quick calibration
ensures accurate reading.
Salinity and Barometric Pressure Compensation
Salt dissolved in solution will be limits oxygen content, Bante 8
series DO meters are capable of compensates the salinity and
barometric pressure after manual input coefficients.
Multi-Measurement Units
The meters can shows various temperature and concentration
units to meet users requirements. For example: mg/L and ppm,
kPa and mmHg, Celsius and Fahrenheit.
Automatic Temperature Compensation
DO probe with a globular shape temperature sensor, it can provide
automatic temperature compensation to ensure accurate measuring
value.
Hold Function
To keep the latest measurement on the display, after taking a reading
press the HOLD key and the measurement remains on the display,
the user can easily view and record data.
?
Power Monitor
During using, The power chip will continuously monitors the battery
level, When the battery is running out of power, The battery icon will
disappear from the screen.
?
Message Indicator
Bante 8 series meters have message indicator, it can shows many
helpful messages like an on-screen manual for easy operation.
?
?
Communication Interface and Data Storage
The meters have real-time date/clock stamps, the memory stores up
to 48 data sets. Press the SAVE key to store the current measured
values and it automatically generates a serial number with time. All
of stored data can then be sent to a computer via the USB port.
Specifications:
Model: Bante820
Dissolved Oxygen Range: 0.0 to 20.0mg/L(ppm)
Resolution: 0.1mg/L
Dissolved Oxygen Accuracy: ±0.5mg/L
% Saturation of Oxygen: 0.0 to 200.0%
Accuracy: ±10.00%
Temperature Compensation: 0 to 40oC, 32 to 104oF, Automatic
Salinity Correction: 0 to 35g/L
Barometric Pressure Correction: 450 to 850mmHg, 60.0 to 112.5kPa
Calibration Points: 1 or 2 points, 100% in air or 0% in solution
Memory: 48 Data sets with Date/Time stamping
Output: USB Communication Interface
Power Requirements: 9V/800mA Battery
Dimensions: 185(L)×88(W)×32(H)mm
Weight: 300g